Hesse PURA-ONE

Two-component HYDRO Acrylate PU Lacquer, high abrasion resistance, tough, well filling, light fast. Top class Multi-coat lacquer for priming and top coating in a wide field of applications. The product can be used on bleached wood. Emission-tested construction product per DIBt [German institute for construction technology] principles,. This lacquer is certified to IMO (flame retardant coating agent for seagoing vessels) and is therefore suitable for the interior fittings on ships. The special formulation of this lacquer also makes it suitable for coating wooden staircases to be creak-free.

DOWNLOAD DATA SHEET
Categories: ,

Description

Mixing ratio (by volume): 10 : 1 HYDRO Hardener HDR 71

For parquet flooring, wood and OSB floors that are subjected to high demands.

  • Light-fast
  • Good transparency
  • Certified according to IMO so it can be applied on ship interiors

Surface Preparation

Professionally laid and prepared parquet or corresponding wooden flooring. The floor must first be sanded back to the bare wood and be dry and free from oil, grease, wax, silicones and sanding dust.

Substrate sanding grits from-to

parquet: 100 – 120

Intermediate lacquer sanding (grits) from-to

120

Finishing

After sufficient drying: initial care with Hesse PROTECT-CLEANER PR 90.

Comments on sanding

The quality and uniformity of the wood and of the lacquer sanding are crucial to the final surface finish. After sanding, remove dust as prescribed.

Application

  • Rolling
  • Spreading

Processing instructions

The floor must first be sanded back to the bare wood and be dry and free from oil, grease, wax, silicones and sanding dust. For renovation or repairs of previously sealed surfaces: Perform a test coating to determine whether the current substrate can be sealed with PURA-ONE. After suitable drying, test the bonding of the complete coating! Shake the lacquer well! Add the correct hardener to the organic lacquer container and immediately shake well for 1 – 2 min. Do not mix in the application container. The mixing ratio must also be accurately observed in the case of partial amounts, and the mixture well shaken. Press the strainer into the outlet opening, fill the lacquer / hardener mixture into a suitable application container and work from this! Only use a mixture within the given application time. Never store product mixed with hardening agent in closed containers. Do not use any electrical stirring devices; risk of forming foam or bubbles! Clean work equipment with water.. Dried lacquer residue can be removed with Hesse CLEANING-AGENT DV 9.

  • The moisture content should be between 8 – 12 %. Please do not use and dry HYDRO lacquers at material and room
    temperatures below 18 °C. The ideal humidity for painting is between 55 and 65 %. In order to avoid problems with
    bonding, please sand the lacquered surfaces before applying fresh lacquer and apply lacquer to the sanded surfaces
    as soon as possible.
  • Woods with a very high wax content such as teak can have a negative effect on bonding in some circumstances.
  • Water-soluble wood contents such as from ash and tannic acid from woods such as oak can initiate changes in colour tones and discolouration in the lacquer. For this reason we recommend a trial lacquering be undertaken as a matter of principle to assess the colour effect, bonding and drying progression under real conditions!

Notes on cleaning and care: Please observe the care instructions in accordance with DIN 18356. Wipe parquet with a slightly damp, not wet, cloth. Please use only neutral, silicone-free, salmiac-free and non-abrasive cleaners. Regular care and cleaning with Hesse PROTECT-CLEANER PR 90 and Hesse INTENSIVE-CLEANER PR 91 increases the life of the sealing.

Particular Instructions

To achieve “R9” slip resistance according to DIN 51130 you need to add 10 % of Hesse HZ 75 anti-slip additive to the final sealing coat! Please shake / stir the additive in well. Critical substrates such as wood block, on-edge lamellar parquet, floor boards, parquet flooring on underfloor heating, etc. require proper pre-treatment with HG 22 / HG 24 to minimise the risk of lateral bonding. To avoid the possibility of staining, please only renovate parquet flooring, which was previously treated with solvent-based systems, with solvent-based systems again! Clean work equipment with water.

Dried lacquer residue can be removed with Hesse CLEANING-AGENT DV 9. Films or carpets must not be placed on the parquet flooring until it has completely hardened. Shake the lacquer well! Spraying: possible; however the addition of water is required. When the hardening agent is well worked in, adjust the spraying viscosity with up to 5 % water. Personal protective equipment and adherence to the instructions for the spraying application. When being used as a flame-retardant coating agent for seagoing vessels, this product may only be combined with other approved and technically suitable products.

ORDER NUMBER

GLOSS LEVEL

CONTAINER SIZE

HDE 51-2

10: matt

4.5 l

HDE 51-4

20: silk matt

4.5 l

HDE 51-7

40: satin gloss

4.5 l

Additional information

Product Type